MON1=1

MON0=0:

7SEG1=1:INV温度检测;

     =2:E-STOP次

     =3:CC-WDT三次

     =4:SLCWDT三次

     =5:电机过电流

     =6:制动器电阻过载

     =7:接触器故障

     =8:终端减速开关故障

     =9:平层开关故障

     =A:称量装置故障

     =B:E1板故障

     =C:UHS/DHS开关故障

     =D:DZ检测回路故障

     =E\F:无

MON0=1:

7SEG1=1:远程复位检测;

     =2:选层器错误16次

     =3:串行故障

     =4:电容器容量不足

     =5:手动运行按钮故障

     =6:速度图形跳转5次

     =7:#LB接触器动作失败5次

     =8:#5接触器动作失败5次 

     =9:#BK1接触器动作失败5次

     =A:#BK2接触器动作失败5次

     =B:LVLT5次

     =C:E1板故障

     =D:风扇故障

     =E\F:风扇或E1板故障

MON0=2:

7SEG1=1:#5  ON故障;

     =2:E-STOP两次

     =3:系统故障

     =4:再复位请求

     =5:PCB基极驱动故障

     =6:DC-CT故障

     =7:无

     =8:浸水感应器故障 

     =9:反浸水动作结束

     =A:#PWD开关指令持续三分钟

     =B:扶手开关保持

     =C:制动器拖动运行结束

     =D:制动器再动作故障

     =E:无

     =F:选层器故障运行16次

MON0=3:

7SEG1=1:MELD过载;

     =2:异常低速

     =3:异常高速

     =4:反转定时

     =5:反向运行

     =6:反转定时器(CWT)

     =7:反转定时器(CWT BS标准)

     =8:逆变器过电压 

     =9:逆变器欠电压

     =A:CC-WDT四次

     =B:SLC-WDT 4次

     =C:逆变器过电流

     =D:SLC E-STOP

     =E:编码器故障(自动)

     =F:编码器故障(手动)

MON0=4:

7SEG1=1:两次E-STOP;

     =2:INV欠电压

     =3:E-STOP F/F复位

     =4:#LB线圈故障

     =5:#5线圈故障

     =6:#BK1线圈故障

     =7:#BK2线圈故障

     =8:上电 

     =9:无

     =A:无

     =B:逆变器充电失败

     =C\D\E\F:无

MON0=5:

7SEG1=1:电气安全回路

     =2:#29锁存

     =3:断电

     =4:INV欠电压

     =5:12V电源故障

     =6:控制屏打开

     =7:手动过载运行

     =8:驱动S/W E-STOP

     =9:管理S/W E-STOP

     =A:无

     =B:异常制动器滑动距离

     =C\D\E\F:无

MON0=6:

7SEG1=1:逆变器欠压;

     =2:PCB基极驱动故障

     =3:INV保护回路动作

     =4:#29锁存

     =5:12V电源故障

     =6:温度开关超75度

     =7:温度开关超90度

     =8:温度开关冷却/接插件断线 

     =9:逆变器过电流

     =A:逆变器过电压

     =B:断电(DC电源故障)

     =C:E1板警告

     =D:DC电源故障

     =E:AC电源故障

     =F:#PWD(电源故障检出)

MON0=7:

7SEG1=1:CC-WDT 5次;

     =2:CC-WDT 4次

     =3:CC-WDT 3次

     =4:SLC-WDT 5次

     =5:SLC-WDT 4次

     =6:SLC-WDT 3次

     =7\8\9\A\B:无

     =C:称量印板低于30度

     =D:称量印板低于30-40度

     =E:称量印板超过60度

     =F:称量装置A/D转换 

MON0=8:

7SEG1=1:#BK1过电流;

     =2:#BK2过电流

     =3:#BK1 DC-CT断线

     =4:#BK2 DC-CT断线

     =5:#BK1线圈故障

     =6:#BK2线圈故障

     =7:#BK1线圈短路

     =8:#BK2线圈短路 

     =9:#BK1 DC-CT故障

     =A:#BK2 DC-CT故障

     =B:#BK1 线圈全部短路

     =C\D\E\F:无

MON0=9:

7SEG1=1:驱动E-STOP

     =2:电机过电流

     =3:不能再启动(驱动S/W)

     =4:MELD过载运行

     =5:TSD开关故障

     =6:称量装置故障

     =7:DC-CT故障

     =8:TSD运行 

     =9:编码器Z相故障

     =A:编码器F相故障

     =B:带定时器电机过电流检测

     =C\D:无

     =E:门切断回路故障

     =F:无

MON0=A:

7SEG1=1:图形-转速跳转

     =2:速度图形跳转异常

     =3:驱动S/W E-STOP

     =4:再生电阻过载

     =5:无

     =6:手动过载运行

     =7:MCP逆变器过电流

     =8:TSD-PAD故障

     =9:称量装置传送故障

     =A:称量装置温度异常

     =B\C\D\E\F:无

MON0=B:

7SEG1=1:10分钟不能用

     =2:16分钟不能用

     =3:不能再启动10分钟

     =4:不能运行10分钟

     =5:不能开门2分钟

     =6:熔丝故障2分钟

     =7:#60故障

     =8:不能开门

     =9:操纵厢故障

     =A:门传感器ON故障

     =B:关人警告

     =C:使用不能警告

     =D:群控故障

     =E:电源故障(层站)

     =F:门感应器OFF故障 

MON0=C:

7SEG1=1:SLC传送故障

     =2:SLC-E STOP

     =3:SLC异常高速

     =4:SLC反转定时器

     =5:开门运行检出

     =6:SLC RAM故障

     =7-F:无

MON0=D:

7SEG1=1:前门BC-CPU1故障

     =2:前门BC-CPU2故障

     =3:前门BC-CPU3故障

     =4:前门BC-CPU4故障

     =5:前门CS-CPU故障

     =6:前门DC-CPU故障

     =7:前门IC-CPU故障

     =8:前门CZ-CPU故障

     =9:SC-CPU故障

     =A:SH-CPU故障

     =B:SC-CPU故障

     =C:SH-CPU故障

     =D:HS-CPU故障

     =E\F:无

MON0=E:

7SEG1=1:后门BK-CPU5异常

     =2:后门BC-CPU6异常

     =3:后门BC-CPU7异常

     =4:后门BC-CPU8异常

     =5:后门CS-CPU异常

     =6:后门DC-CPU异常

     =7:后门IC-CPU异常

     =8:后门CZ-CPU异常

     =9:#BK1接触器动作失败5次